Skip Navigation LinkslindQST / Waterborne Calculator
Product category
Product
Function
Product length
L
m
Type
Water connection
mm
Air connection
mm
Connection type
Distribution profile
Static nozzle pressure loss
Δpstat
Pa
Primary airflow rate
qa
Number of products
Description
Control valve
Flexible hoses




Room attenuation
Dr
dB
Cooling
Capacity need
Pt
W
Room air temperature
tr
°C
Temperature gradient in room
tg
K
Primary air temperature
tai
°C
Water inlet temperature
twi
°C
Temperature difference water circuit
Δtw
K

Architect Circum-12-125-A1-1.2-60-15

Add to project

Water flow rate in cooling circuit is below the minimum permitted qwmin = 0.025 l/s

  • Product information
  • Results
  • View in 3D

Exposed supply air beam
  • Images
  • Product description
  • Related documents
  • Videos
MISSING

Architect is an active chilled beam for exposed installation that provides great freedom of choice in design. Easy applicable with three predefined cover design solutions with great flexibility to create a customised design, without affecting the function and performance. One big advantage is that you can do you planning without having to decide on the design. This allows you to retrofit the design in a simple way.

Architect can be equipped with cooling, heating, ventilation, Regula Secura condensation guard, built-in valves, actuators and built-in lighting (special).

  • Freedom in architectonic design
  • JetCone technology
  • Low building height – 175 mm
  • Adaptable with lighting
  • Eurovent certified

MISSING
  • Results
    Cooling
    Temp. difference between room air temp. and mean water temp.
    Δtrw
    K
    Nominal water capacity
    Pwnom
    W
    Water flow rate
    qw
    l/s
    Corrected water capacity
    Pw
    W
    Capacity air
    Pa
    W
    Total Capacity
    Pt
    W
    Pressure loss water in product
    ΔpwP
    kPa
    Sound power level
    LwA
    dB(A)
    Sound pressure level
    LpA
    dB(A)
    Water capacity / active length
    Pw/Lact
    W/m
    Mixed air temperature
    tam
    °C
  • Total results
    Primary airflow rate
    qat
    l/s
    Water flow rate
    qwt
    l/s
    Total Capacity
    Pt
    W
  • Additional results
    Penetration length, horizontal (min)
    Xlp
    m
    Penetration length, horizontal (max)
    Xlp
    m
    JetCone setpoint's
    Added pressure loss in connection
    Δpa
    Pa
    Total air pressure loss in duct
    Δpt
    Pa
    Primary airflow rate / active length
    qa/Lact
    l/s/m
    Induction ratio
    qai/qa
    Induction air volume
    qai
    l/s
    Mixed air volume
    qam
    l/s

© Copyright 2024, Lindab AB. All rights reserved. lindQST.com is owned by Lindab AB all images, technical data and other material found on this site belongs to Lindab AB. Please contact Lindab if you wish to use our material in other matters.